be.OT Secure Industrial Platform

European OT cybersecurity platform embedded in its own network, to protect critical infrastructure such as power grids, water supply, and industrial environments end to end

Security that lives inside the OT network

Security built into industrial gateways of the OT network - be.OT - Teldat
OT cybersecurity platform that protects every point of the network, from the remote site to the control center, with a single policy and centralized visibility of all industrial assets.

 

  • Security built into the routers and gateways that already carry OT traffic
  • More than 1,000 industrial protocol signatures, such as IEC 60870-5-104, IEC 61850, and DNP3
  • Passive asset inventory and a single management console for the entire OT network
  • Centralized, distributed, or hybrid deployment, according to the needs of each location
  • European manufacturer whose equipment helps meet NIS2, CRA, and IEC 62443 compliance

Critical infrastructure under attack

Critical infrastructure under cyber attack - power grid - NIS2 - Teldat

Critical infrastructure, from power grids to water supply and industrial plants, is no longer a theoretical target. In late December 2025, Poland foiled an attack against cogeneration plants and management systems for wind and solar farms, which its government linked to Russian services. In July 2026, attackers exploited internet-connected PLCs across more than 30 water systems in Minnesota (U.S.), locking some operators out and forcing equipment to be operated manually. In October 2026, a wave of attacks raised refrigerator temperatures at hundreds of supermarkets in France and, in early November, in Belgium and other European countries, with product losses valued in the millions of euros.

On top of this comes growing regulatory pressure. The NIS2 Directive requires essential entities, among them those in the energy sector, to manage their cybersecurity risks, and the Cyber Resilience Act (CRA) requires security by design from manufacturers, with vulnerability reporting in force since September 2026 and full application in December 2027.

At the same time, the shutdown of 2G and 3G networks, primarily in Europe but also in other parts of the world, forces the replacement of many devices deployed in the field. This is the opportunity to build in security from day one, rather than adding it afterward as a separate layer.

OT security inside the network - Teldat

Security inside the network

Protection is built into the industrial gateways and edge devices that carry the traffic, instead of being added as a separate layer that must be deployed, cabled, and maintained at every site.

Designed for OT environments - industrial protocols - Teldat

Designed specifically for OT environments

Inspection and control purpose-built for industrial environments, with more than 1,000 OT protocol signatures, such as IEC 60870-5-104, IEC 61850, DNP3, and Modbus, and easy customization of the customer’s proprietary protocols.

Compliance by design - NIS2, CRA and IEC 62443 - Teldat

Compliance by design

Supports the requirements of NIS2, CRA, and IEC 62443, with events and traceability that ease audits, and is backed by a European manufacturer with control over its supply chain and firmware.

Operation at scale with zero-touch provisioning - Teldat

Operation at scale

Zero-touch provisioning to deploy and maintain large fleets of devices across thousands of dispersed locations, with a consistent security policy, no configuration drift, and no unnecessary site visits.

OT cybersecurity: protecting without disrupting

Operational technology (OT) is what controls physical processes: electrical substations, water treatment plants, production lines, or urban traffic systems. Protecting these networks is not the same as protecting a corporate network. In an industrial environment, availability comes first, and a security measure that introduces complexity or degrades operation can be worse than the risk it aims to avoid.

Several factors make this environment unique. Assets are distributed across plants, remote stations, or isolated equipment, with variable connectivity. Equipment and platforms from different manufacturers coexist, many designed to last for decades. Remote access by suppliers and engineers is necessary, but must be done with control and traceability. And communications use numerous industrial protocols, such as Modbus, DNP3, IEC 60870-5-104, IEC 61850, and OPC UA, which require specific inspection that conventional IT firewalls do not understand.

On top of this is a visibility problem: you cannot protect what you cannot see. Unknown or unauthorized devices are a threat, and telling normal behavior from anomalous behavior in machine-to-machine flows requires an approach centered on OT protocols, with specific detection, passive inventory, and progressive response.

That is why OT cybersecurity rests on three ideas:

  • Protection at the edge: inspecting and controlling traffic where it originates, even when the link to the control center fails.
  • Zero-trust access with industrial protocol awareness: each user or supplier reaches only the asset they need, and every session is inspected, not just authenticated.
  • Unified visibility: seeing the inventory, flows, and alarms across the entire network, from the plant floor to the corporate network, in a single console.
OT cybersecurity from level 0 plant floor to level 5 corporate network - Teldat
A common mistake is bringing the corporate network’s tools and processes into the industrial network. Active scans can affect sensitive equipment, patches cannot always be applied without stopping the process, and reliance on an external cloud clashes with latency and data sovereignty requirements. That is why a sound approach combines measures that run on the communications equipment itself with centralized management, and makes it possible to decide, site by site, where each flow is inspected.

All of this must cover every layer of the network, from the level 0 sensors and actuators to the level 5 corporate network, and do so while complying with an increasingly demanding regulatory framework, with NIS2, the CRA, and the IEC 62443 standard as references.

The Teldat be.OT Solution: the secure industrial platform

be.OT Secure Industrial Platform is Teldat’s proposal for protecting industrial and critical-infrastructure networks. It is not a single device but an OT cybersecurity architecture that brings together the protection of be.Safe Pro and the visibility of be.Safe XDR under one umbrella, with protection distributed across every point of the network and managed from a single platform with centralized control and visibility.

be.Safe PRO is the platform’s protection layer. It brings together next-generation firewalls (NGFW/UTM), intrusion prevention and detection (IPS/IDS), application control, and segmentation. It includes more than 1,000 signatures and controls for industrial protocols and makes it easy to customize the customer’s proprietary protocols.

Policies are defined once and applied consistently across all sites, with no configuration drift. OT protocol inspection and segmentation between devices run close to where the traffic originates, with low latency and without depending on the link to the control center. In addition, events are logged and traceable, which eases NIS2 and IEC 62443 audits.

be.Safe PRO industrial NGFW and IPS with OT protocol inspection - be.OT - Teldat
be.Safe XDR passive OT asset inventory and anomaly detection - be.OT - Teldat

The platform adds Zero-Trust Access (ZTNA) with OT protocol awareness: each engineer or supplier reaches only the industrial asset they need, and every session is inspected, not just authenticated.

be.Safe XDR is the visibility and audit layer. A passive probe, with one-way data flow, automatically discovers connected assets (IP and MAC, name, manufacturer, operating system and version, protocols, asset type, and first and last seen), without adding load or risk to production systems and without packets leaving the customer’s premises. It also shows machine-to-machine flows, detects protocols and anomalies, and generates reports and alarms, all in a single console spanning from the plant floor (level 0) to the corporate network (level 5).

Both layers can be deployed centrally, distributed, or hybrid. With hybrid SASE, the customer decides whether functions run on premises or in the cloud, and keeps a single policy across both modes.

These functions reach the network through Teldat’s industrial equipment, such as the Regesta Smart v2 (Secure Industrial Gateway) and Imber (Secure M2M Shield) families.

be.OT – Use Cases

Substations and power grids - OT cybersecurity use case - Teldat

Substations and power grids

Secure connectivity between substations, RTUs, PLCs, and smart meters, and the control center, with cybersecurity built into the equipment itself.

Industrial M2M communications - OT cybersecurity use case - Teldat

Industrial M2M communications

Protection of sensors, robots, RTUs, and connected machines at remote locations, with secure tunnels to the corporate data center.

Smart cities - OT cybersecurity use case - Teldat

Smart cities

Traffic lights, streetlights, water, video, and municipal services protected end to end and managed from a single control center.

Substations and power grids

Secure connectivity between substations, RTUs, PLCs, and smart meters, and the control center, with cybersecurity built into the equipment itself.

Challenge

A power utility operates hundreds or thousands of remote sites, such as substations and transformer centers, with RTUs, PLCs, and smart meters of different generations and no security staff on site. It must interconnect them with the control center, allow third-party remote access, and demonstrate compliance with NIS2 and the CRA, often through manual processes.

In addition, many of its devices still rely on 2G and 3G networks that operators are shutting down, and there is rarely an up-to-date inventory of what is actually connected at each substation. Any security measure must reinforce operational continuity, not degrade it, and the equipment must run for a decade or more with minimal maintenance.

Solution

Substation cybersecurity with Regesta Smart industrial gateway - IEC 60870-5-104 - Teldat
The Regesta Smart v2 family of Industrial Gateways protects traffic where it originates and sends it through IPSec tunnels to security instances in the data center, where a centralized policy is applied and visibility, inventory, and alarms are obtained.

With the Custos family of Industrial Edge devices, inspection of protocols such as IEC 60870-5-104 and the inventory run locally at the edge and keep working even if the link goes down.

Connectivity is flexible: 5G, LTE, 450 MHz, satellite networks, PRIME PLC, and BPL. Everything is managed from a single console, with zero-touch provisioning to deploy and maintain fleets of thousands of devices.

Why Teldat?

16 years of experience with tens of thousands of units deployed at leading power utilities, European manufacturing with ENS High level, and a design meant to last 10 to 15 years without intervention, with a single European supplier for connectivity and security.

Industrial M2M communications

Protection of sensors, robots, RTUs, and connected machines at remote locations, with secure tunnels to the corporate data center.

Challenge

Industrial, water, energy, and utility companies are connecting more and more sensors, robots, RTUs, and machines at remote sites, with equipment from many different manufacturers and no IT staff on site.

Many of these devices are left exposed or with weak credentials, and real incidents prove it. In 2026, internet-exposed PLCs were exploited across more than 30 water systems in the United States, and in 2025 a weak password made it possible to manipulate a valve for four hours.

Companies need controlled remote access for their suppliers, to know which devices are at each site, and to do so without adding complexity or jeopardizing operational continuity. Small teams cannot afford a different security tool for every site.

Solution

Industrial M2M communications protected by Imber Secure M2M Shield - SASE - Teldat
Imber Secure M2M Shield is installed at each remote site and protects machine-to-machine traffic with NGFW in SASE mode. All traffic travels through IPSec tunnels to security instances in the customer’s data center or in the cloud, where inspection, policy, and security updates are concentrated.

Third-party remote access follows the zero-trust model: each engineer reaches only the asset they need, and the session is inspected at the industrial protocol level. Signatures and security updates arrive automatically from the cloud. The result is a consistent policy across all sites and a single console.

Why Teldat?

A single platform that combines connectivity, next-generation firewall, and OT inspection. This translates into fewer boxes, fewer suppliers, and fewer points of failure, and with them the attack surface and the total cost, with a single point of support.

Smart cities

Traffic lights, streetlights, water, video, and municipal services protected end to end and managed from a single control center.

Challenge

A smart city connects traffic lights, trams, sensors, cameras, water, and municipal services across networks of very different kinds, some of them unencrypted. The attacks are already real.

In 2023, a cyberattack on the traffic management system of Olsztyn (Poland) disrupted the traffic lights at nearly 100 intersections for several weeks, unauthorized radio commands brought about 20 trains to a standstill, and that same year a group compromised pressure-monitoring equipment at a municipal water utility in Pennsylvania.

City councils, with small technical teams, must protect infrastructure scattered across blocks or districts, know what is connected, and comply with NIS2 without multiplying cost or operational complexity. In addition, each service usually depends on a different supplier, which makes a single view harder to achieve.

Solution

Smart city OT cybersecurity with edge protection per district - Teldat
Each block or district is protected with an edge device that inspects traffic where it originates and sends it through IPSec tunnels to the city’s control center, where policy, visibility, and alarms are concentrated.

In a centralized architecture, inspection runs on shared security instances. In a distributed architecture, each device applies the policy locally, with segmentation and zero trust between devices, and keeps protecting even if the link goes down. SD-WAN controllers maintain a single policy, and the two modes can be combined within the same city.

Why Teldat?

Flexible architecture (centralized, distributed, or hybrid) that protects each block with the same type of equipment, with modular connectivity and backed by a European manufacturer with tens of thousands of units deployed.

Read our latest Blog Posts

Understanding the technology behind heat pipes

Understanding the technology behind heat pipes

Heat pipes transfer heat on electronic devices & industrial applications, using the heat transition principle, to transfer to heat sinks within a cooling system. Heat pipes have clear advantages over other heat dissipation methods. What are heat pipes? Heat pipes...

read more
Improving device reliability and redundancy

Improving device reliability and redundancy

In a previous article we looked at how to mathematically calculate the reliability of electronic equipment. That is, the probability of it working correctly for a given period of time. This is best characterised by the Mean Time Between Failure (MTBF), or its...

read more
Teldat
Company›